CCTV 12+1 HFFR

Application: 
Used in closed circuit camera systems. HFFR does not transmit flames during the fire, does not emit toxic and corrosive gases.
Cable Construction: 
  • Coaxial
    : 75 OHM Coaxial Cable from Mini Coaxial to RG 59 series
  • Inner Conductor
    : Twisted or Electrolytic Mono Copper
  • Insulation
    : Physically Foamed Polyethylene
  • 1.Screen
    : AL-PET or CU-PET 100% Cover
  • 2.Screen
    : Braid made of Aluminum/Tinned Copper/Copper Wires
  • Sheath
    : HFFR Compound
Control Cores: 
  • Conductor
    : Electrolytic Twisted Copper
  • Insulation
    : HFFR Compound
  • General Screen
    : AL-PET 100% Cover
  • Outer Sheath
    : HFFR Compound
Electrical Data: 
  • Operating Voltage
    : 250 V
  • Testing Voltage
    : 1,2 kV
  • Insulation Resistance (Min.)
    : >2000 MΩ / km
  • Operating Temperature
    : -30ºC ~ + 70ºC
  • Bending Radius
    : 10xD mm
  • Impedance
    : 75 ± 3 Ω
  • Effective Capacity
    : 57 ± 2 pF/m
  • Conductor Resistance
    : 0,22 mm² = 79 Ω/km
  • Velocity of Propagation
    : % 82 ± 2
  • Smoke Density Test
    : IEC 61034-2 / VDE 0482-1034-2 / EN 61034-2
  • Corrosive Gas Test
    : IEC 60754-2 / VDE 0482-267-2-3 / EN 50267-2-3
  • Hallogen-Free Test
    : IEC 60754-1 / VDE 0482-267-2-1 / EN 50267-2-1
  • Flame Retardancy Test
    : IEC 60332-1-2 / VDE 0482-332-1-2 / EN 60332-1-2
Core Quantity x Nominal Cross-Section (mm²)Outer Diameter (mm)Cable Weight (kg/km)Standard Legth (mt)
COAX (7x0.20) + 12x0.228.5093100/500/1000
RG 59 + 12x0.228.5095100/500/1000