RG 59 U/4 HFFR

Application: 
Used as CATV distribution cable and used in low-attenuation required systems. HFFR does not transmit flame during fire, does not exhale toxic and corrosive gases.
Cable Construction: 
  • Inner Conductor
    : 0,80 mm Electrolytic Mono Copper
  • Insulation
    : 3,70 mm Physically Foamed Polyethylene
  • 1.Screen
    : Al-Pet Foil, 100% Cover
  • 2.Screen
    : Braid made of Aluminum/Tinned Copper Wires
  • Sheath
    : 5,80 mm HFFR Compound
  • Packing
    : 100/500/1000 m
Electrical Data: 
  • Operating Voltage
    : 1,1 kV
  • Testing Voltage
    : 2,5 kV
  • Insulation Resistance
    : >2000 M Ω/km 20°C
  • Operating Temperature
    : -30°C ~ + 70°C
  • Bending Radius
    : 15xD mm
  • Impedance
    : 75 ± 3 Ω
  • Effective Capacity
    : 53 ± pF/m
  • Velocity of Propagation
    : % 82 ± 2
  • Smoke Density Test
    : IEC 61034-2 / VDE 0482-1034-2 / EN 61034-2
  • Corrosive Gas Test
    : IEC 60754-2 / VDE 0482-267-2-3 / EN 50267-2-3
  • Hallogen-free Test
    : IEC 60754-1 / VDE 0482-267-2-1 / EN 50267-2-1
  • Flame Retardancy Test
    : IEC 60332-1-2 / VDE 0482-332-1-2 / EN 60332-1-2
Attenuations dB/100m (Max): 
Return Loss dB (min): 
  • 5-470 MHz : 
    > 20 dB
  • 470-1200 MHz : 
    > 18 dB
  • 1200-2000 MHz : 
    > 16 dB
  • 2000-3000 MHz : 
    > 15 dB