H03Z1Z1-F / H05Z1Z1-F

Application: 
They are used in dry, closed and moist places where there is little mechanical constraint and in home appliances. Their Halogen-free flame retardant isolate prevents the spread of flames and the emition of toxic gases during fire.
Cable Construction: 
  • Conductor
    : Electrolytic Flexible Thin Copper
  • Insulation
    : HFFR Compound
  • Sheath
    : HFFR Compound
  • Twisting
    : Twisted as layers on fixed pitch
  • Packing
    : 100-500-1000 mt Reel
Electrical Properties: 
  • Nominal Voltage : H03Z1Z1-F : 300/300 V
                                   H05Z1Z1-F : 300/500 V
  • Testing Voltage (AC) : 2000 V
  • Operating Temperature : -5 C° ~ +70 C°      
  • Max. Short Circuit Temperature : +160 C° 
  • Min. Bending Radius : 10 x D
  • Smoke Density Test: IEC 61034-2 / VDE 0482-1034-2 / EN 61034-2
  • Corrosive Gas Test : IEC 60754-2 / VDE 0482-267-2-3 / EN 50267-2-3
  • Hallogen-Free Test : IEC 60754-1 / VDE 0482-267-2-1 / EN 50267-2-1
  •  Flame Retardancy Test : IEC 60332-1-2 / VDE 0482-332-1-2 / EN 60332-1-2

 Product Code 

 

 Nominal Cross-Section 

(mm²) 

 Outer Diameter

(mm) 

 Total Weight 

(kg/km) 

 Conductor Resistancec 

Ω/km (20 C°) 

 Current Carrying Capacity (A) 
H03Z1Z1-F 2x0.50 5.20 38 39 3
H03Z1Z1-F 2x0.75 5.40 43 26 6
H03Z1Z1-F 3x0.50 5.60 46 39 3
H03Z1Z1-F 3x0.75 5.80 54 26 6
H03Z1Z1-F 4x0.50 6.10 56 39 3
H03Z1Z1-F 4x0.75 6.30 66 26 6
H05Z1Z1-F 2x0.75 6.20 54 26 6
H05Z1Z1-F 2x1.00 6.60 62 19.5 10
H05Z1Z1-F 2x1.50 7.40 81 13.3 15
H05Z1Z1-F 2x2.50 9.20 128 7.98 20
H05Z1Z1-F 3x0.75 6.60 64 26 6
H05Z1Z1-F 3x1.00 7.00 75 19.5 10
H05Z1Z1-F 3x1.50 8.10 104 13.3 15
H05Z1Z1-F 3x2.50 10.00 163 7.98 20
H05Z1Z1-F 4x0.75 7.20 80 26 6
H05Z1Z1-F 4x1.00 7.90 97 19.5 10
H05Z1Z1-F 4x1.50 9.00 131 13.3 15
H05Z1Z1-F 4x2.50 10.90 201 7.98 20